GROW GM65-216 DC10-24V Barcode Scanner Access Control System Relay Output For Door Express Box Support Bar Code Qr Code

stars, based on 0reviews
$35.80now$28.80 piece
Quantity Price
10+ $27.65
999items available
Contact Us
OR
Description

DC10-30V, Relay Output, Relay Time: 0.5s-20s or 0.5s
Managed by SET button or remote control(add/delete bar code to different three database,change relay time and so on)
 
·Power supply: DC10V--24V
·Standby current: 6mA(DC12V)
·Output: Relay(Max. current: 10A)
·Bar code capacity:
Group 1: 20 pieces
Group 2: 20pieces
Group 3:One-time bar code:10 pieces
·Control board management: SET Button or Remote control
 
 

Decoding Ability

1D: EAN- 8,EAN-13,UPC-A,UPC-E,Code 39,Code 93,Code 128,EAN128,Codebar,industrial 2 of 5,Interleave 2 of 5,Matrix 2 of 5,MSI,postal code ect
2D: PDF417,QR Code ,Data Matrix ect
 
 

GM65-216 Circuit board diagram


GM65-216 Connection reference diagram



 Instructions for GM65-216 access control
1.SET Button:
1.1 Press SET button shortly,system in register state and indicator light flash fast, register bar code and when hearing music means register successfully.Can be registered continuously when system in register state; if no need adding more, wait a few seconds to exit.(Can register 40 pieces bar code when press SET button, register in group 1, group 2 in turn)
1.2 When back to factory default, press SET button until hear “Di” long beep and
music,means initialization operation successful.
 
2.Remote Control:
Red indicator lighted means in programming stated, music means operation successful, default password: 123456,password length: 6 numbers
2.1 Change password: Press *password*1*new password*new password#
2.2 Register bar code:
Register Group 1: Press *Password*2*1# 20 pieces capacity
Register Group 2: Press *Password*2*2# 20 pieces capacity
Register Group 3: Press *Password*2*3# 10 pieces capacity One-time bar code
Exit bar code in register state when press * button or waiting a few seconds
2.3.  Empty: Press *password*3*password#
2.4.  Delay time for closing relay: Press *password*5*SS #; SS from 00 to 20, SS means the closing time for relay(from 0.5s to 20s), e.g.: 00 means 0.5s, 20 means 20s; Default time is 5s. (e.g.:Set 2s: Press *Password*5*02#)
2.5.  Delete bar code:
Delete Group 1: Press*Password*6*1#
 Delete Group 2: Press*Password*6*2#
Delete Group 3: Press*Password*6*3#
2.6.  Scan Head Lighting:
Close: Press*Password*7*0#
Open: Press*Password*7*1#
2.7.  Scan Head Collimation:
Close: Press*Password*8*0#
Open: Press*Password*8*1#
2.8.  Password Using: Press *password and relay closed, press # and relay opened.
 
3.Function Set:
When chose 1, closing time of the relay is 5s after pass bar code(5s is default time, and it can be adjusted by remote control from 0.5-20s); When chose 2, closing time of the relay is 0.5s after pass bar code.
 
 
 

·Provide User Manual 
 
You can download the GM65-216 user manual from this website link:
 
GM65-216 Operation Video on Youtube: https://youtu.be/GQTzka9svik
 
*If purchase GM65 and K216 seperately, it will can not use.
 
 






Barcode Scanner Scan Head Size:

Barcode Scanner Control Board Size:


 
 
 
 


Brand Name:
grow
Model Number:
GM65-216
Power supply:
DC10V--24V
Standby current:
6mA(DC12V)
Output:
Relay(Max. current: 10A)
Bar code capacity:
50